Low Leakage Current |
||||||||||||||||||||||
|
|
|
|||||||||||||||||||||
|
||||||||||||||||||||||
| ELECTRICAL CHARACTERISTICS | |||||||
| Working Voltage | 6.3 V to 50 V | ||||||
| Operating Temperature | -
40 |
||||||
| Capacitance Range | 0.47
~ 1,000 |
||||||
| Capacitance Tolerance |
|
||||||
| DC Leakage
Current( |
0.002
CV or 4 (after 3 minutes application of rate voltage) |
||||||
| Dissipation
Factor at 120Hz, 25 |
WV(V) |
6.3 | 10 | 16 | 25 | 35 | 50 |
|
DF(%) |
24 | 20 | 16 | 14 | 12 | 10 | |
|
Load
Life : 1000 hours with W.V at 85 Capacitance Change: Within 20% of initial value. Dissipation Factor: Not exceed 150% of initial requirement. Leakage Current: Not exceed the initial requirement. ¡@ |
|
Shelf
Life : 500 hours, no voltage applied at 85 |
|
Capacitance Change: Within 20% of initial value. Dissipation Factor: Not exceed 150% of initial requirement. Leakage Current: Not exceed 200% of initial requirement. |
¡@
Supertech copyright 2005.11