NON-POLAR 120Hz |
||||||||||||||||||||||
|
|
|
|||||||||||||||||||||
|
||||||||||||||||||||||
|
ELECTRICAL CHARACTERISTICS |
|||||||||
| Working Voltage | 6.3 V to 100 V | ||||||||
| Operating Temperature | -
40 |
||||||||
| Capacitance Range | 0.47
~ 2,200 |
||||||||
| Capacitance Tolerance |
|
||||||||
| DC Leakage
Current ( |
0.03
CV or 3 |
||||||||
| Dissipation
Factor at 120Hz, 25 |
WV(V) | 6.3 | 10 | 16 | 25 | 35 | 50 | 63 | 100 |
| DF(%) | 26 | 24 | 22 | 20 | 16 | 14 | 12 | 10 | |
|
For capacitor whose capacitance exceeds 1000uF, the value of DF(%) is increased by 2% for every additional 1000uF |
|||||||||
|
Load
Life : 1000 hours with W.V at 85 Capacitance Change: Within 20% of initial value. Dissipation Factor: Not exceed 150% of initial requirement. Leakage Current: Not exceed the initial requirement. ¡@ |
|||||||||
|
Shelf
Life : 500 hours, no voltage applied at 85 |
|||||||||
|
Capacitance Change: Within 20% of initial value. Dissipation Factor: Not exceed 150% of initial requirement. Leakage Current: Not exceed 200% of initial requirement. |
|||||||||
¡@
Supertech copyright 2005.11