| Application Caution | BACK |
|
1. A surge excess of the specifies Maximum Peak Current may cause short circuit or mechanical damage. The following measures are recommended. |
|||||||||||||
![]() |
![]() |
||||||||||||
|
1) Location of the over current protector (circuit breaker or current fuse ) shall be in the power line to the circuit( Location A) or in series with Varistor ( Location B)
|
|||||||||||||
| 2) It is recommended that a fuse listed in the table shall be put in location A or B. | |||||||||||||
|
3) In case that Varistor is used in line to ground, the ground fault circuit interrupter shall be applied in locate A or thermally coupled fuse shall be applied in location C. |
|||||||||||||
|
4) Fuse mounted Type K or Type P are available for V1 and V2 applications. |
|||||||||||||
|
5) Varistor shall not be used near the flamable materials. |
|||||||||||||
|
2. When Varistor is molded at en-user, molding resin materials shall be carefully selected, otherwise Varistor,s long term stability could degrade. |
|||||||||||||
|
3. Varistor shall not be used near heat generating device and free from direct sunlight. Varistor shall be used with in the specified Operating Temperature Range. |
|||||||||||||
|
4. Varistor Shall be free from dust, metal powder, dew and sea wind. A protective box is recommended to prevent the unit from those. |
|||||||||||||
| ¡@ | |||||||||||||
| ¡@ | |||||||||||||