| --------- Electrical --------- | |||||||||||||||||||||||||||||||||||||||||||
|
Standard Test condition |
Environmental
conditions under which every measuring is done without doubt on the
measuring results. Unless specially specified, temperature, relative
humidity are 5 to 35 |
¡@- |
|||||||||||||||||||||||||||||||||||||||||
| Varistor Voltage | The voltage between two terminals with the specified measuring current CmA DC applied is called Vc or V CmA The measurement shall be made as fast as possible to avoid heat affection. |
To meet the specified value ¡@ |
|||||||||||||||||||||||||||||||||||||||||
| Maximum Allowable Voltage¡@ | The maximum sinusoidal RMS voltage or maximum DC voltage that can be applied continuously in the specified environmental temperature range. | ||||||||||||||||||||||||||||||||||||||||||
| Clamping Voltage | The maximum voltage between two terminals with the specified standard impulse current ( 8/20 us )illustrated below applied. | ||||||||||||||||||||||||||||||||||||||||||
|
|
|||||||||||||||||||||||||||||||||||||||||||
| Rate Power |
The power that can be applied in the specified ambient temperature. |
||||||||||||||||||||||||||||||||||||||||||
| Maximum Energy | The
maximum energy within the varistor voltage chahge change of |
||||||||||||||||||||||||||||||||||||||||||
| Max. Peak Current (Withstanding Surge Current) | 2 times | The Max.
current within the varistor voltage change of |
|||||||||||||||||||||||||||||||||||||||||
| 1 time | The
Max. current within the varistor voltage change of |
||||||||||||||||||||||||||||||||||||||||||
| Temperature Coefficient of Varistor Voltage |
|
-
0.05%/ |
|||||||||||||||||||||||||||||||||||||||||
| Capacitance | Capacitance
shall be measured at 1KHz |
To meet the specified value | |||||||||||||||||||||||||||||||||||||||||
| Dissipation Factor | Dissipation
Factor shall be measured at 1KHz |
||||||||||||||||||||||||||||||||||||||||||
| Withstanding Voltage (Body Insulation) |
The specified voltage shall be applied both terminals of the specimen connected together and metal foil closely wrapped round its body for 1 minute. Electrical breakdown shall be examined.
|
No breakdown |
|||||||||||||||||||||||||||||||||||||||||
| Impulse Life ( I ) |
The change of Vc shall be measured after the impulse listed below is applied 10,000times continuously with the interval of 10 seconds at room temperature.
|
||||||||||||||||||||||||||||||||||||||||||
|
Impulse Life ( II ) |
The
change of Vc shall be measured after the impulse listed below is applied
10,000 times continuously with the interval of 10 seconds at room
temperature.
|
||||||||||||||||||||||||||||||||||||||||||
|
Note: Varistor voltage change of forward direction shall be measured in the test of uni-pole surge life and DC load life. |
|||||||||||||||||||||||||||||||||||||||||||
|
Characteristics |
Test Methods/Description |
Specifications |
|||||||||||||||||||||||||||||||||||||||||