BACK

 FEATURES 

   Temp. curve    

 Package  

Capacitance / SIZE / Volt.

  1. Large capacitance in small sizes.

  2. Linear temperature coefficient of capacitance
  3. Low loss at wide range of frequency.
  4. Large capacitance in small sizes.
 APPLICATIONS

 Transistorized, low voltage electronic circuits for by-pass coupling, frequency determination,

   in which dielectric losses, HI-IR and Cap. Stability are not major importance.

 SPECIFICATIONS

  1. Operating Temperature range :    - 25C ~ +85C

  2. Capacitance :   Within the specified to tolerance at  25C, 1kHz, 0.1Vrms.

  3. Rated working voltage :   16VDC, 25VDC, 50VDC
  4. Test Voltage :    200%  of rated voltage.

  5. Insulation resistance ( IR ) at  25C :

                                                             16V : 100M or 10MuF whichever is smaller.

                                                     25V, 50V : 1000M or 20MuF whichever is smaller.

  6. Dissipation  factor :    AT  25C,  1kHz, 1 0.2Vrms.

                                                                             DF <= 5%  for  16V

                                                                             DF <= 7%  for  25V, 50V

  7. Life Test : 

             After application of 200% of the rate voltage of 1000 hours at 85C,  Capacitors shall meet

             the following . Measurement shall be made after 24 hours exposure at room temperature.

¡@

Temp. Char.  Y5P / Y5R Y5U / Y5T Y5V
Change of Capacitance   10% 20% 30%
Dissipation  Factor

7.5%

7.5%

Insulation Resistance

500 M or 50 MuF whichever is less

  8. Humidity Test :

          The capacitors shall be exposed in the ambient temperature of 40C and 95%R.H. for 500

          hours. The capacitors shall meet following after 24 hours exposure at room temperature.

¡@

Temp. Char.  Y5P / Y5R Y5U / Y5T Y5V
Change of Capacitance   10% 20% 30%
Dissipation  Factor

7.5%

7.5%

Insulation Resistance

500 M or 50 MuF whichever is less

  9. Temperature compensating material :

¡@

Max. Capacitance Change

Form 25C

Applicable Temperature Range
Y5P 10% - 25C ~ + 85C
Y5R 15% - 25C ~ + 85C
Y5T +  22%,   - 33% - 25C ~ + 85C
Y5U +  22%,   - 56% - 25C ~ + 85C
Y5V +  22%,   - 82% - 25C ~ + 85C

¡@