BACK

 FEATURES 

1kv ~ 5kv

  1. Large capacitance in small sizes.

  Package  

Capacitance / SIZE / Volt.

  2. Linear temperature coefficient of capacitance
 SPECIFICATIONS 

  1. Operating Temperature range :    - 25C ~ +85( NPO, SL, Y5E, Y5P, Y5U, Y5V )

                                                           +10C ~ +85( Z5U, Z5V )

  2. Capacitance :   Within the specified to tolerance at  25C, 1kHz, 1 0.2Vrms.

                               1MHz for Class I and 1KHz for Class II

  3. Rated working voltage :   1KV,  2KV,  3KV,  4KV,  5KV
  4. Test Voltage :    200%  of rated voltage with 50mA Max.

  5. Insulation resistance ( IR ) at  25C :   10000M or 200MuF whichever is smaller.

  6. Dissipation  factor :    AT  25C,  1kHz, 1 0.2Vrms.

            Class l (1MHz) : C > 30pF ... Q >= 1000 ( C : capacitance )

                                     C<= 30pF ... Q >= 400 + 20C

            Class II (1KHz) : DF <=  2.5% for  Y5E / Y5P / Y5U / Z5U

                                     DF <=  3% for  Z5V

                                     DF <=  5% for  Y5V

7. Life Test : 

             After application of 200% of the rate voltage of 1000 hours at 85C,  Capacitors shall meet

             the following . Measurement shall be made after 24 hours exposure at room temperature.

¡@

Temp. Char.  NPO / SL Y5E / Y5P / Y5U / Z5U Y5V / Z5V
Change of Capacitance   20% 20% 30%
Dissipation  Factor

3%

5%

Insulation Resistance

10000 M or 200 MuF whichever is less

  8. Humidity Test :

          The capacitors shall be exposed in the ambient temperature of 40C and 95%R.H. for 500

          hours. The capacitors shall meet following after 24 hours exposure at room temperature.

¡@

Temp. Char.  NPO / SL Y5E / Y5P / Y5U / Z5U Y5V / Z5V
Change of Capacitance   20% 20% 30%
Dissipation  Factor

3%

5%

Insulation Resistance

10000 M or 200 MuF whichever is less

¡@

  9. Temperature compensating material :

¡@

Max. Capacitance Change

Form 25C

Applicable Temperature Range
NPO 0 60 ppm/C - 25C ~ + 85C
SL ( +350 ~- 1000  ) 60 ppm/C - 25C ~ + 85C
Y5E 4.7% - 25C ~ + 85C
Y5P 10% - 25C ~ + 85C
Y5U +  22%,   - 56% - 25C ~ + 85C
Z5U +  22%,   - 56% +10C ~ + 85C
Y5V +  22%,   - 82% - 25C ~ + 85C
Z5V +  22%,   - 82% +10C ~ + 85C

¡@